Plate Designations
SUPERCHANGER units are designed so that a uid which
enters the A” plate circuit (nozzles S1, S2, M1 or M2) always
ows in the A” circuit only. Fluid which enters the “B” plate
circuit (nozzles S3, S4, M3 or M4) always ows in the “B” circuit
only. Facing the stationary frame, the right side is always the
A” side, while the left side is always the “B” side. The “A” and
“B” term refers to the gasket orientation. When looking at the
gasketed side of the plate, an A” plate becomes a “B” plate when
reversed (turned upside down). If the ow comes in and out on
the left side, it is a “B” orientation.
NOTE: Every other plate has to be rotated 180° A-B-A-B in order
to prevent mixing. The rst plate in the unit is called a “D” plate
and has a special gasket arrangement. This arrangement keeps
the fl ow from contacting the stationary frame. The last is called
the “E” plate and is gasketed normally.
3
2
Items 1–4 indicate nozzle locations
3
2
To and from
additional
plates
Movable end frame side
A side
1
B side
Stationary end frame side
4
4
1
Figure 11
Plate orientation for the UX, SX, GC and GF Series.
Figure 12
Gasket orientation.
A” plate
“B” plate